1.
J Occup Environ Hyg ; 19(10-11): 663-675, 2022.
Article in English | MEDLINE | ID: covidwho-2028921

ABSTRACT

The COVID-19 pandemic has affected the world and caused a supply shortage of personal protection equipment, especially filtering facepiece respirators (FFP). This has increased the risk of many healthcare workers contracting SARS-CoV-2. Various strategies have been assessed to tackle these supply issues. In critical shortage scenarios, reusing single-use-designed respirators may be required. Thus, an easily applicable and reliable FFP2 (or alike) respirator decontamination method, allowing safe re-use of FFP2 respirators by healthcare personnel, has been developed and is presented in this study. A potent and gentle aerosolized hydrogen peroxide (12% wt) method was applied over 4 hr to decontaminate various brands of FFP2 respirators within a small common room, followed by adequate aeration and storage overnight. The microbial efficacy was tested on unused respirator pieces using spores of Geobacillus stearothermophilus. Further, decontamination effectiveness was tested on used respirators after one 12-hr shift by swabbing before and after the decontamination. The effects of up to ten decontamination cycles on the respirators' functionality were evaluated using material properties, the structural integrity of the respirators, and fit tests with subjects. The suggested H2O2 decontamination procedure was proven to be (a) sufficiently potent (no microbial recovery, total inactivation of biological indicators as well as spore inoculum on critical respirator surfaces), (b) gentle as no significant damage to the respirator structural integrity and acceptable fit factors were observed, and (c) safe as no H2O2 residue were detected after the defined aeration and storage. Thus, this easy-to-implement and scalable method could overcome another severe respirator shortage, providing enough flexibility to draft safe, effective, and logistically simple crisis plans. However, as highlighted in this study, due to the wealth of design and material used in different models and brands of respirators, the decontamination process should be validated for each FFP respirator model before its field implementation.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Pandemics/prevention & control , COVID-19/prevention & control , Decontamination/methods , Equipment Reuse , Ventilators, Mechanical
2.
Environ Int ; 167: 107364, 2022 09.
Article in English | MEDLINE | ID: covidwho-1895021

ABSTRACT

Since the start of the current COVID-19 pandemic, for the first time a significant fraction of the world's population cover their respiratory system for an extended period with mostly medical facemasks and textile masks. This new situation raises questions about the extent of mask related debris (fibers and particles) being released and inhaled and possible adverse effects on human health. This study aimed to quantify the debris release from a textile-based facemask in comparison to a surgical mask and a reference cotton textile using both liquid and air extraction. Under liquid extractions, cotton-based textiles released up to 29'452 ± 1'996 fibers g-1 textile while synthetic textiles released up to 1'030 ± 115 fibers g-1 textile. However, when the masks were subjected to air-based extraction scenarios, only a fraction (0.1-1.1%) of this fiber amount was released. Several metals including copper (up to 40.8 ± 0.9 µg g-1) and iron (up to 7.0 ± 0.3 µg g-1) were detected in acid dissolved textiles. Additionally the acute in vitro toxicity of size-fractionated liquid extracts (below and above 0.4 µm) were assessed on human alveolar basal epithelial cells. The current study shows no acute cytotoxicity response for all the analyzed facemasks.


Subject(s)
COVID-19 , Humans , Pandemics , Textiles
3.
Sci Rep ; 12(1): 4938, 2022 03 23.
Article in English | MEDLINE | ID: covidwho-1758378

ABSTRACT

After the spread of COVID-19, surgical masks became highly recommended to the public. They tend to be handled and used multiple times, which may impact their performance. To evaluate this risk, surgical masks of Type IIR were submitted to four simulated treatments: folding, ageing with artificial saliva or sweat and washing cycles. The air permeability, mechanical integrity, electrostatic potential, and filtration efficiency (FE) of the masks were measured to quantify possible degradation. Overall, air permeability and mechanical integrity were not affected, except after washing, which slightly degraded the filtering layers. Electrostatic potential and FE showed a strong correlation, highlighting the role of electrostatic charges on small particle filtration. A slight decrease in FE for 100 nm particles was found, from 74.4% for the reference masks to 70.6% for the mask treated in saliva for 8 h. A strong effect was observed for washed masks, resulting in FE of 46.9% (± 9.5%), comparable to that of a control group with no electrostatic charges. A dry store and reuse strategy could thus be envisaged for the public if safety in terms of viral and bacterial charge is ensured, whereas washing strongly impacts FE and is not recommended.


Subject(s)
COVID-19 , Respiratory Protective Devices , COVID-19/prevention & control , Filtration , Humans , Masks
4.
Chimia (Aarau) ; 75(3): 215-218, 2021 Mar 31.
Article in English | MEDLINE | ID: covidwho-1154188

ABSTRACT

When the SARS-CoV-2 pandemic started,[1] science came to the immediate attention of the broad public. People and politicians were hanging on every word of medical doctors, virologists, molecular biologists, data scientists and many others in the hope of finding other protective measures than those used for centuries such as basic hygiene, distance, or quarantine. Here, at the Institute of Chemistry and Biotechnology at the Zurich University of Applied Sciences (ZHAW) we were also willing to provide scientific solutions to overcome the pandemic. Together with our partners from industry, we contributed to the development of a Swiss vaccine, are working on filters for active ventilated full protective suits and are developing tests to show the efficacy and safety of an active antiviral textile that allows controlled virus inactivation through an electrochemical reaction by applying a small current.


Subject(s)
COVID-19 , Universities , Academies and Institutes , Humans , Pandemics , SARS-CoV-2
5.
Swiss Med Wkly ; 151: w20459, 2021 01 18.
Article in English | MEDLINE | ID: covidwho-1055197

ABSTRACT

BACKGROUND: SARS-CoV-2 is a respiratory virus. Transmission occurs by droplets, contact and aerosols. In medical settings, filtering facepiece (FFP) respirators are recommended for use by personnel exposed to aerosol-generating procedures. During the COVID-19 pandemic, the demand for FFP respirators exceeded their supply worldwide and low-quality products appeared on the market, potentially putting healthcare workers at risk. AIMS: To raise awareness about variations in quality of imported FFP respirators in Switzerland during the COVID-19 pandemic, to draw attention to the current directives regulating the market launch of FFP respirators in Switzerland, to provide practical support in identifying suspicious products or documents and, finally, to offer strategies aimed at reducing the distribution of low-quality FFP respirators in the future. METHODS: Three Swiss laboratories, Spiez Laboratory and Unisanté in partnership with TOXpro SA individually set up testing procedures to evaluate aerosol penetration and fit testing of FFP respirators imported into Switzerland during COVID-19 pandemic. Additionally, Spiez Laboratory visually inspected the products, examined the certification documents and crosschecked the product information with international databases. RESULTS: Between 31 March and 15 June 2020, 151 FFP respirators were analysed. The initial assessment performed before testing allowed a reduction of up to 35% in the number of FFP respirators sent to Spiez Laboratory for evaluation, for which product information found to be faulty. After filtration efficiency evaluation and fit testing, 52% and 60% of all products tested by Spiez Laboratory and Unisanté-TOXpro SA, respectively, did not meet the minimum performance requirements established independently by the three Swiss laboratories. CONCLUSION: The demand for FFP respirators exceeded the supply capacity from established suppliers of the Swiss market. New production and import channels emerged, as did the number of poor-quality FFP respirators. FFP respirators remaining in stocks should be checked for conformity before being used, or eliminated and replaced if quality does not meet standards.


Subject(s)
COVID-19/prevention & control , N95 Respirators/standards , COVID-19/transmission , Humans , In Vitro Techniques , N95 Respirators/supply & distribution , Product Labeling , Respiratory Protective Devices/standards , Respiratory Protective Devices/supply & distribution , SARS-CoV-2 , Switzerland
6.
Antimicrob Resist Infect Control ; 9(1): 88, 2020 06 17.
Article in English | MEDLINE | ID: covidwho-601144

ABSTRACT

INTRODUCTION: Transmission of SARS-CoV-2 to health care workers (HCW) poses a major burden in the current COVID-19 pandemic. Unprotected exposure to a COVID-19 patient is a key risk factor for HCWs. Transmission mainly occurs by droplet transmission, or by aerosol generating procedures. Respirators such as filtering face piece masks (FFP2), also called respirators, are required to prevent transmission during aerosol generating procedures, as part of the personal protective equipment (PPE) for HCWs. However, many HCW were infected due to lack of PPE, or failure to use them. Therefore, the worldwide shortage of respirators triggered the development of reprocessing used FFP2 respirators or N95 respirators as standard in the US. Our proposal with H2O2 plasma sterilization for decontamination allows to reprocess FFP2, while they still meet the filtration efficiency required by EN 149. The protocol is simple, uses available resources in hospitals and can be rapidly implemented to decrease the shortage of respirators during this crisis. The goal of the study was the evaluate if respirators can be reprocessed and still fulfill the requirements for filtration efficiency outlined by EN 149. METHODS: Used FFP2 respirators - Model 3 M Aura™ 1862+ - were sterilized using a low temperature process hydrogen peroxide (H2O2), V-PRO® maX Low Temperature, a FDA (Food and Drug Administration) approved method to decontaminate FFP2 respirators. Decontaminated respirators were further checked for residual peroxide by a single-gas detector for H2O2. The total inward leakage of the protective respirators was quantitatively tested with 10 test persons in an atmosphere charged with paraffin aerosol according to the European Standard EN 149. The fit factor was calculated as the inverse of the total inward leakage. RESULTS: Ten new and ten decontaminated FFP2 respirators were tested for filtration efficiency. None of the respirators exceeded the maximum acceptable concentration of peroxide. More than 4000 respirators have been reprocessed so far, at cost of approximately 0.3 Euro/piece. CONCLUSIONS: FFP2 respirators can be safely reprocessed once after decontamination with plasma peroxide sterilization, whereafter they still fulfill EN 149 requirements. This allows to almost double the current number of available FFP2 respirators.


Subject(s)
Coronavirus Infections/prevention & control , Infection Control/instrumentation , Infectious Disease Transmission, Patient-to-Professional/prevention & control , Masks/standards , Pandemics/prevention & control , Personal Protective Equipment/standards , Pneumonia, Viral/prevention & control , Aerosols , Betacoronavirus/isolation & purification , COVID-19 , Coronavirus Infections/epidemiology , Device Approval , Equipment Design/standards , Eye Protective Devices , Humans , Hydrogen Peroxide , Infection Control/methods , Infection Control/standards , Materials Testing , Pneumonia, Viral/epidemiology , Risk Factors , SARS-CoV-2 , United States/epidemiology